Skip to content

Tech tip2 min read

Tech Tip 118: IMAGELINK Microfilm Processing Chemicals

IMAGELINK G 3231C and G 3343C concentrates, ready-to-use table-top solutions and EcoPos 305 chemistry, with dilution and processing data.

Tech Tip 118: IMAGELINK Microfilm Processing Chemicals

IMAGELINK processing chemicals are a new generation of environmentally friendly, high-capacity solutions for trouble-free processing. The result is less chemical handling, lower consumption and less waste.

Highlights

  • Developer G 3231C and Fixer G 3343C concentrates for medium tank and deep tank processors, in 5 liter containers
  • Ready-to-use solutions that need no dilution for table-top processors
  • Dedicated chemistry for IMAGELINK EcoPos 305 film

Concentrates for IMAGELINK film

Parameter Value
Products Developer G 3231C, Fixer G 3343C
Packaging 5 liters
Dilution ratio 1 + 3
Processing temperature 27°C (80°F)
Processing time 60 seconds
Automatic replenishment About 175 ml of diluted solution per meter of film

Ready to Use solutions

  • 5L IMAGELINK ARCHIVE RTU DEV
  • 5L IMAGELINK ARCHIVE HF DEV
  • 5L IMAGELINK ARCHIVE RTU FIX

These solutions suit all table-top processors such as the IMAGELINK Archive Processor, Agfa or Microform FP500, Cordell and similar short-cycle processors, and deliver consistent results without special mixing or monitoring equipment.

IMAGELINK EcoPos 305 film chemistry

Parameter Value
Products IMAGELINK EcoPos 305 Developer, IMAGELINK EcoPos 305 Fixer
Packaging 4 x 5L
Dilution ratio 1 + 2
Suitable processors All deep tank processors
Temperature (starting point) 37°C (98.6°F)
Automatic replenishment (starting point) 250 ml per meter of 105 mm film

Source:Eastman Park Micrographics(epminc.com)(opens in a new tab)

Frequently asked questions

What processing parameters are needed for IMAGELINK film with Developer G 3231C and Fixer G 3343C concentrates?

The processing temperature is 27°C (80°F), processing time is 60 seconds, dilution ratio is 1 + 3, and automatic replenishment is about 175 ml of diluted solution per meter of film.

In what packaging are Developer G 3231C and Fixer G 3343C concentrates supplied and for which processors are they suitable?

They are supplied in 5 liter containers and are suitable for medium tank and deep tank processors.

Which table-top processors are suitable for IMAGELINK ARCHIVE ready-to-use solutions?

They suit all table-top processors such as the IMAGELINK Archive Processor, Agfa or Microform FP500, Cordell and similar short-cycle processors.

What are the starting temperature and automatic replenishment rate for IMAGELINK EcoPos 305 film chemistry?

The starting temperature is 37°C (98.6°F) and the starting automatic replenishment rate is 250 ml per meter of 105 mm film.

What is the dilution ratio for IMAGELINK EcoPos 305 Developer and Fixer?

The dilution ratio for IMAGELINK EcoPos 305 Developer and Fixer is 1 + 2.

Attachments

Comments

No comments yet. Be the first to share your view.

Leave a comment

Answer with digits

More to read

  • ORTHOPANTOMOGRAPH OP 3D Pro User Manual

    Tech tip · Dental Imaging

    ORTHOPANTOMOGRAPH OP 3D Pro User Manual

    User manual and technical specifications for the OP 3D Pro digital dental imaging system with panoramic, cephalometric and Cone Beam 3D programs.

    Instrumentarium Dental

  • Tech Tip 91: Choosing the Correct IMAGELINK Product

    Tech tip · Microfilm

    Tech Tip 91: Choosing the Correct IMAGELINK Product

    IMAGELINK camera, duplicating, Archive Writer and COM films and processing chemicals grouped by equipment and application, with catalog numbers.

    Eastman Park Micrographics

Planning a new imaging room or upgrading equipment?

Tell us about your center. Our application specialists will recommend the right configuration and prepare a tailored proposal.