Computed Radiography· Veterinary
Agfa project
Clinica della Brughiera Equine Clinic and the Agfa CR 15-X and Equine DR 35
Italian equine clinic Clinica della Brughiera uses the CR 15-X digitizer and wireless Equine DR 35 detector for fast imaging in the clinic and ambulance.
This case study is a reference published by Agfa.
Source: agfaradiologysolutions.com

Clinica della Brughiera, a small clinic near Varese, Italy, specializing in equine care, provides 24-hour service, a mobile diagnostic ambulance at horse races and orthopedic surgery. To meet its need for accuracy, quality, ease of use and speed, the clinic uses the Agfa CR 15-X digitizer and Equine DR 35 digital detector.
Highlights
- The CR 15-X is ideal for emergencies: the plate is exposed at the scene and read later in the digitizer.
- The image can be provided as hardcopy or softcopy directly in the ambulance.
- The Equine DR 35 is wireless, compact and portable, and sends images directly to the workstation.
- Dedicated MUSICA for Large Animals image processing delivers high image quality.
- The equipment was used in the mobile equine clinic at the Longines Global Champions Tour 2014.
The clinic's needs
Since 1980 the clinic has focused on diagnosing equine disease and has a team of 10, including 7 veterinarians. Horses from all over Italy and Switzerland come for radiography, ultrasound, MRI, endoscopy and other tests. Most injuries to racehorses happen in training or competition, so the clinic's ambulance was also equipped with a radiography system to allow fast diagnosis of fractures in emergencies.
The Agfa solution
- CR 15-X digitizer: cost-effective, high-throughput, compact CR with high image quality from MUSICA, easy operation and maintenance, and a modular, robust design with adjustable speed.
- Equine DR 35 detector: direct radiography for horses, a mobile solution with a notebook running NX software, wireless image transfer and fast workflow.
Results
According to the clinic director, sending images directly to the workstation has made the DR 35 the fastest radiography solution in the ambulance and the clinic. Feedback from this experience on the LGC tour is being used to develop Agfa solutions for equine care.
Installed products
Agfa CR Digitizers
More projects
View all
VeterinaryAgfa project2021VeterinaryItaly
Case Study: Clinica della Brughiera, Italy, Equine Imaging with Agfa DR and CR (2021 Edition)
Dr. Alessandro Centinaio's experience with the Agfa DX-D 45C mobile DR and CR 15-X at Clinica della Brughiera and international equestrian events.
Source: agfaradiologysolutions.com
VeterinaryAgfa project2019VeterinaryItaly
Case Study: Dr. Alessandro Centinaio and Clinica della Brughiera, Italy, with Agfa DR and CR
Equine orthopedic vet Alessandro Centinaio cut pre-purchase imaging time from 1 hour to 20 minutes with the Agfa DX-D 45C mobile DR and CR 15-X.
Source: agfaradiologysolutions.com
Computed RadiographyAgfa project2013VeterinaryKota Kinabalu, Sabah, Malaysia
Century Animals Medical Centre in Malaysia and the Agfa CR 10-X
Century Animals Medical Centre in Sabah, Malaysia installed the CR 10-X and DRYSTAR 5302, the city's first in-house digital radiography system for vets.
Source: agfahealthcare.com