Skip to content
CPI Indico 100 RF X-ray Generator - Image 1 of 2
CPI Indico 100 Generators

CPI Indico 100 RF X-ray Generator

Model
Indico 100 RF
Brand
CPI

Indico 100 RF generator for pulsed and conventional fluoroscopy and radiography, at 40 to 100 kW plus a 100 kW Special Procedures model.

Description

Indico 100 RF generator for pulsed and conventional fluoroscopy and radiography, at 40 to 100 kW plus a 100 kW Special Procedures model.

  • Pulsed and conventional fluoroscopy, compatible with digital and analog RAD and RF systems
  • RAD or RF models at 40, 50, 65, 80 and 100 kW and a 100 kW model for Special Procedures (Indico 100 SP)
  • Multiple AEC and ABS interfaces, remote fluoroscopy control
  • 1024 anatomical techniques, 6 programmable image receptors and multilingual
  • Dose Area Product (DAP) or Air Kerma display (optional)

Indico 100 Touchscreen (RAD and RF)

  • 15 inch Touchscreen display with PowerPC-based CPU
  • More than 20,000 anatomical programs (APR) and technique selection with memory
  • Multilingual support, backup and restore, custom graphical interface
  • Adjustable viewing angle, wall mount and optional hand switch

GenWare service software

  • Generator programming through GenWare or the operator console
  • Very quick and easy installation
  • System diagnostics for remote analysis
  • Automatic X-ray tube calibration
  • Library of more than 300 X-ray tubes

Technical specifications

General
Control processor16 Bit CPU
StarterIntegrated Low Speed Starter or Dual-Speed Starter
Auxiliary cabinet120/240 VAC (optional)
CertificationsFDA, CFDA, CE
X-ray generator
RAD or RF power levels32/40/50/65/80/100 kW
Special Procedures power levels80/100 kW
Generator frequencyUp to 400 kHz
Inverter moduleFET Inverter Modules
Continuous fluoroscopy kVp range40 - 125 kV in 1 kV steps
kVp accuracy±(2% + 1 kV) for 70 - 85 kV, ±(5% + 1 kV) for 40 - 150 kV
High voltage ripple (continuous)< 1 kV at 100 kV
Continuous fluoroscopy mA range0.5 - 10 mA in 0.1 mA steps
mA accuracy±(5% + 1 mA) for > 50 ms, ±20% for ≤ 6.7 mA
Pulsed fluoroscopy kVp range40 - 125 kV in 1 kV steps
Pulsed fluoroscopy mA rangeUp to 99 mA in 0.1 mA steps
Pulse rate30, 15, 7.5, 3, 1 @ 60 Hz; 25, 12, 6, 3, 1 @ 50 Hz
Pulse width1 - 40 ms in 1 ms steps, up to 50% duty cycle
High level continuous fluoroscopyUp to 20 mA (40 to 100 kW models)
Power
Maximum voltage150 kV standard
Power supply1 Phase 230 VAC, 3 Phase 400 or 480 VAC

Accessories

  • Touchscreen console with wall mount (optional)
  • Hand switch (optional)
  • Auxiliary cabinet (optional)
  • DAP or Air Kerma display (optional)

Where this system is installed

Projects where this product was installed and commissioned.

View all